65 research outputs found

    Multislice computed tomography coronary angiography

    Get PDF
    __Abstract__ Computed Tomography (CT) imaging is also known as "CAT scanning" (Computed Axia

    Cardiac magnetic resonance in cocaine-induced myocardial damage

    Get PDF
    A 54-year-old male with history of cocaine abuse underwent trans-thoracic echocardiography that showed hyper-echogenicity of the basal segments of the septum and infero-lateral wall of the left ventricle. The patient underwent cardiac CT that reported diffuse non-obstructive CAD. Cardiac MR showed LGE patterns consistent with non-ischemic myocardial damage associated with cocaine abuse

    Chronic pseudoaneurysm of the left ventricle

    Get PDF
    We present a case of a 55-year-old men who suffered a silent myocardial infarction four years earlier and presented with exertional dyspnoea. Cardiac magnetic resonance imaging (CMR) and Multislice computed tomography (MSCT) was performed and revealed a giant pseudoaneursym of the lateral wall of the left ventricle with the presence of a thrombus in the lateral wall of the pseudoaneursym. We present this case since excellent non-invasive evaluation of the pseudoaneursym was feasible using state-of-the-art imaging modalities. Information on left ventricular geometry and function as well as myocardial viability and coronary anatomy is available when both MSCT and CMR are performed. This combined approach of these two imaging modalities provide clinically relevant information and may guide therapeutic decision making

    Noninvasive detection of a ruptured aneurysm at a basilar artery fenestration with submillimeter multisection CT angiography

    Get PDF
    The criterion standard for the detection of intracranial aneurysms is digital subtraction angiography. MR imaging and CT provide good accuracy in the evaluation of brain arteries and aneurysms. We herein report a case of a ruptured aneurysm at a basilar artery fenestration. The diagnosis was assessed with 16-row multisection CT angiography and was confirmed by using digital subtraction angiography. The patient was successfully treated with coil placement

    Visual claudicatio: Diagnosis with 64-slice computed tomography

    Get PDF
    We present a case of a 78-year-old male referred presented to our institution with amaurosis fugax after walking 20 steps ("visual claudicatio"). Duplex ultrasound was not able to visualize the carotid arteries. Multislice computed tomography (Sensation 64 Cardiac, Siemens, Germany) of the cerebro-vascular circulation was performed from its origin at the level of the aortic arch to the circle of Willis. The investigation demonstrated a complete occlusion of both common carotid arteries at their origin and a severe origo stenosis of both vertebral arteries. An important collateral circulation of the vertebral arteries through the minor vessels of the neck was also displayed. Both comunicans posterior arteries were small but patent. The intra-cranial arteries were patent. Multislice CT of the cerebro-vascular circulation is an optimal tool for a comprehensive evaluation when duplex ultrasound fails

    Follow-up of internal mammary artery stent with 64-slice CT

    Get PDF
    We present a case of 81-year-old woman complaining chest pain after minimal efforts who underwent multiple coronary artery bypass grafts (CABGs) during the last 15 years. A significant in-stent re-stenosis was found at ostium of left internal mammary artery (LIMA). A non-invasive CT coronary angiography (CT-CA) was performed after 6-month follow-up. CT-CA is a reliable non-invasive technique for the follow-up of stents in coronary artery bypass grafts

    Diagnostic accuracy of multislice computed tomography coronary angiography is improved at low heart rates

    Get PDF
    Purpose: Assess the effect of heart rate on diagnostic accuracy for the detection of significant coronary artery stenosis using 16-row multislice computed tomography (MSCT). Material and methods: About 120 patients (105 males; 59 ± 11 years) with suspected coronary artery disease who underwent conventional coronary angiography (CA) and MSCT-CA were retrospectively enrolled for the study. Patients underwent a MSCT-CA (Sensation 16, Siemens, Germany), with the following protocol: Collimation 16 × 0.75 mm, gantry rotation time 420 ms, feed/rotation 3.0 mm, kV 120, mAs 400-500. The protocol for contrast material administration was 100 ml of Iodixanol (Visipaque 320 mg l/ml, Amersham, UK) at 4 ml/s and the delay was defined with a bolus tracking technique. In all patients the mean heart rate (HR) during the scan was used as a criteria to divide the population in two groups of 60 patients each. In one group (Low HR) the 60 patients with lower heart rates, and in the other group (High HR) the patients with higher heart rates. In the two groups diagnostic accuracy (per coronary segment) for the detection of significant stenosis (≥50% lumen reduction) was evaluated in vessels ≥2 mm of diameter using quantitative CA as reference standard. The difference in diagnostic accuracy were compared with a Chi2 test and a p < 0.05 was considered significant. Results: There was no significant difference between the two groups regarding age, gender, weight, mean intravascular attenuation, and calcium score. Overall 1310 (652 for Low HR and 658 for High HR) segments with 219 (105 for Low HR and 114 for High HR) significant lesions were available for the analysis. The average heart rate was 52 ± 4HU and 63 ± 5HU for Low HR and High HR, respectively (p < 0.001). The sensitivity and specificity were 92 and 96% for Low HR and 90 and 92% for High HR (p < 0.05). There were 22 vs. 44 false positives, and 8 vs. 12 false negatives in the Low HR and High HR, respectively. Conclusion: Increasing HR significantly deteriorates diagnostic accuracy in MSCT-CA

    Cardiac computed tomography: indications, applications, limitations, and training requirements: Report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology

    Get PDF
    As a consequence of improved technology, there is growing clinical interest in the use of multi-detector row computed tomography (MDCT) for non-invasive coronary angiography. Indeed, the accuracy of MDCT to detect or exclude coronary artery stenoses has been high in many published studies. This report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT (WG 5) of the European Society of Cardiology and the European Council of Nuclear Cardiology summarizes the present state of cardiac CT technology, as well as the currently available data concerning its accuracy and applicability in certain clinical situations. Besides coronary CT angiography, the use of CT for the assessment of cardiac morphology and function, evaluation of perfusion and viability, and analysis of heart valves is discussed. In addition, recommendations for clinical applications of cardiac CT imaging are given and limitations of the technique are describe

    The effect of open lung ventilation on right ventricular and left ventricular function in lung-lavaged pigs

    Get PDF
    INTRODUCTION: Ventilation according to the open lung concept (OLC) consists of recruitment maneuvers, followed by low tidal volume and high positive end-expiratory pressure, aiming at minimizing atelectasis. The minimization of atelectasis reduces the right ventricular (RV) afterload, but the increased intrathoracic pressures used by OLC ventilation could increase the RV afterload. We hypothesize that when atelectasis is minimized by OLC ventilation, cardiac function is not affected despite the higher mean airway pressure. METHODS: After repeated lung lavage, each pig (n = 10) was conventionally ventilated and was ventilated according to OLC in a randomized cross-over setting. Conventional mechanical ventilation (CMV) consisted of volume-controlled ventilation with 5 cmH2O positive end-expiratory pressure and a tidal volume of 8-10 ml/kg. No recruitment maneuvers were performed. During OLC ventilation, recruitment maneuvers were applied until PaO2/FiO2 > 60 kPa. The peak inspiratory pressure was set to obtain a tidal volume of 6-8 ml/kg. The cardiac output (CO), th
    • …
    corecore